Home › Heat Pump Systems › Goodman 2.5-Ton 14.5 SEER2 Heat Pump System

Goodman · Heat Pump System · 2.5 ton
Goodman 2.5-Ton 14.5 SEER2 Heat Pump System
Model: GLZS4BA3010 + AMST30BU1300
14.5 SEER27.8 HSPF2R-32208/230V 1-ph
$3,695 / system
Free shipping nationwide · ships in 3–5 business days
Local pickup in Dallas–Fort Worth: $3,045
Order this system Call (945) 495-5771
New equipment, manufacturer warranty registered by Northgate. Monthly payments available at checkout.
Backup (auxiliary) heat kit
| 10 kW (HKTSN10X1) | Included · 10 kW backup heat kit |
|---|---|
| 15 kW (HKTSD15XB) | +$130 · 15 kW backup heat kit |
Heat Pump: GLZS4BA3010
Goodman 2.5 Ton Up to 15.2 SEER2 R-32 Heat Pump Condenser
- Up to 15.2 SEER2 & 7.8 HSPF2 (depends on matched indoor unit)
- Single-stage rotary compressor with crankcase heater
- SmartShift® quiet, reliable defrost
- Suction-line accumulator, bi-flow filter drier, high & low pressure switches
- R-32 refrigerant, factory charged for 15 ft of line
- Meets 2023 Florida Building Code hurricane-wind integrity when anchored
| Dimensions (W × D × H) | 29 × 29 × 39.5 in |
|---|---|
| Weight | 175 lb (ship 190 lb) |
| Capacity | 30,000 BTU/h cooling & heating (2.5 ton) |
| SEER2 / HSPF2 | Up to 15.2 / up to 7.8 (depends on matched indoor unit) |
| Compressor | Rotary, single-stage |
| Refrigerant | R-32 |
| Factory charge | 81 oz (for 15 ft of 3/8" liquid line) |
| Voltage / Phase | 208/230V, 1-phase, 60 Hz |
| Rated load amps (RLA) | 11.2 A |
| Locked rotor amps (LRA) | 52.5 A |
| Minimum circuit ampacity (MCA) | 15 A |
| Max overcurrent protection (MOCP) | 25 A |
| Condenser fan | 1/6 HP PSC motor, 0.95 FLA |
| Liquid line | 3/8" OD, sweat |
| Suction line | 3/4" OD; 3/4" suction valve |
| Sound level | 77 dBA |
| Cabinet | Heavy-gauge galvanized steel, Architectural Gray powder paint |
| Approvals | AHRI certified, ETL listed |
| Warranty | 10-year parts limited warranty with online registration within 60 days of install |
Air Handler: AMST30BU1300
Goodman 2.5 Ton R-32 Multi-Position ECM Air Handler with Internal TXV
- Multi-position: upflow, downflow or horizontal
- Multi-speed ECM blower (9 speed taps)
- Factory-installed TXV and R-32 leak sensor
- All-aluminum evaporator coil, 21" depth for attic installs
- Tool-less filter access, low-leak cabinet (<2% at 1.0" H2O)
- Accepts field-installed 3 to 25 kW heat kits
| Dimensions (W × D × H) | 17.56 × 21 × 53.44 in |
|---|---|
| Ship weight | 129 lb |
| Cooling capacity | 30,000 BTU/h |
| Refrigerant | R-32 (factory R-32 sensor) |
| Metering device | TXV, factory installed |
| Blower | 3/4 HP multi-speed ECM, 10" × 6" wheel |
| Blower full load amps | 4.5 A |
| Minimum circuit ampacity (MCA) | 5.6 A |
| Max overcurrent protection (MOCP) | 15 A |
| Voltage / Phase | 208/240V, 1-phase, 60 Hz |
| Liquid line | 3/8" |
| Suction line | 3/4" |
| Drain connection | 3/4" FPT, with secondary drain |
| Air flow direction | Multi-position (vertical or horizontal) |
| Electric heat | Field-installed 3 to 25 kW heat kits |
| Approvals | AHRI certified, ETL listed, UL 60335-2-40 |
| Warranty | 10-year parts limited warranty with online registration within 60 days of install |
Related equipment
Carrier 2.5-Ton Heat Pump System with Front-Return Air HandlerGH5SAN53000A + FMA5X3000AL
$3,400
Carrier 2.5-Ton Heat Pump System with Front-Return Air Handler (Piston)GH5SAN53000A + FMA5L3000AL
$3,300
Carrier 2.5-Ton Heat Pump System with Ceiling-Mount Air HandlerGH5SAN53000A + FMC5Z3000AL
$3,650
Carrier 2.5-Ton Heat Pump SystemGH5SAN53000A + FJ5ANXB30L00
$3,770
Goodman 2-Ton 15.2 SEER2 Heat Pump SystemGLZS4BA2410 + AMST24BU1300
$3,350
Goodman 3-Ton 15 SEER2 Heat Pump SystemGLZS4BA3610 + AMST36CU1300
$4,125
Goodman 3.5-Ton 15.2 SEER2 Heat Pump SystemGLZS4BA4210 + AMST42CU1300
$4,375
Goodman 4-Ton 15.2 SEER2 Heat Pump SystemGLZS4BA4810 + AMST48CU1300
$4,675
